Factory worker checking a DC-powered fuel transfer pump and its wiring connections at an industrial site

Choose a 12V or 24V DC fuel-transfer pump only after checking the supply where it will connect. The CE-40DC, CE-70-A-DC and CE-80-DC pump options have DC ratings; the AC220V option belongs to the CE-204 and CE-206 dispensers, not these pumps.

What should you verify at the transfer point?

Check whether the supply at the connection is AC or DC, then measure its voltage before choosing a pump version. For a fixed industrial installation, check the transfer point itself rather than relying on a nearby socket.

  • Verify AC or DC power and measure the voltage at the planned connection.
  • For DC power, choose a pump version that matches 12V or 24V.
  • Check the chosen version’s current against the supply, wiring and circuit protection.
  • Record the liquid and the flow you need in L/min.
  • Match the pump’s inlet and outlet sizes to your hose and fittings.
  • Decide whether you need a transfer pump or a dispenser with delivery controls.
  • Get a quote for the exact version, showing the INR price with GST included.

Which transfer pumps have 12V and 24V versions?

CE-40DC and CE-80-DC have 12V and 24V versions; CE-70-A-DC also has a 12V/24V rating. Pick the voltage that matches your DC supply, then compare flow, liquid use and connections.

CE-40DC is rated at 40 L/min for diesel and kerosene. It has 3/4-inch inlet and outlet connections and a 30-minute work cycle. CE-80-DC is rated at 80 L/min for diesel transfer, with 1-inch connections.

The CE-70-A-DC is rated at 70 L/min with 3/4-inch connections. Check its suitability for your liquid before purchase; its voltage and flow figures alone do not settle that choice.

How do the listed current ratings affect the choice?

CE-40DC draws 22A at 12V and 12A at 24V. CE-80-DC draws 44A at 12V and 21A at 24V. Use the figure for the exact model and voltage when checking the supply, cable and circuit protection.

CE-70-A-DC has a 4A current figure, but that figure is not assigned to either its 12V or 24V rating. Get the current requirement for the version you intend to buy. Do not use CE-40DC’s or CE-80-DC’s rating in its place.

A supply set up for a 12V CE-40DC must not be treated as ready for a 12V CE-80-DC: their ratings are 22A and 44A respectively. Have the electrical installer size the wiring and protection for the selected pump; no cable or fuse size is specified here.

What AC voltage options are listed, and for which equipment?

The CE-40DC, CE-70-A-DC and CE-80-DC are DC-only pumps, with no 220V AC or 110V AC version. Do not connect a DC pump directly to an AC supply or choose it for an AC-only point based on flow rate.

The CE-204 and CE-206 dispensers each offer DC12V, DC24V and AC220V. Their AC220V option applies to those dispensers, not to CE-40DC, CE-70-A-DC or CE-80-DC. Both dispensers have a 20-80 L/min flow range.

If you need pump-only transfer from an AC supply, establish the voltage rating of an actual AC transfer-pump model before buying. If you need dispensing controls, compare the CE-204 and CE-206 instead. This distinction matters when a transport company is specifying fleet fuelling, or a textile mill is setting up a fixed diesel point.

How should flow rate and connections influence the pump choice?

CE-40DC is rated at 40 L/min, CE-70-A-DC at 70 L/min, and CE-80-DC at 80 L/min. Compare those rates with the job, but settle the liquid, voltage and connection checks too.

Transfer pump Voltage option Flow rate Inlet and outlet
CE-40DC 12V or 24V DC 40 L/min 3/4 inch
CE-70-A-DC 12V/24V DC 70 L/min 3/4 inch
CE-80-DC 12V or 24V DC 80 L/min 1 inch

The 1-inch CE-80-DC connection differs from the 3/4-inch connections on the other two pumps. Check your planned hose and fittings before selecting a model. For other site checks beyond voltage, use these diesel transfer-pump selection points.

Compare quotes for the same model, voltage and connections, with GST shown clearly. Buying from an Indian supplier can make a version-specific quote easier to check, but verify the product’s origin before claiming Make in India status.

For a fuel installation, check which PESO and Factory Act requirements apply to the site before work begins. Do not treat a voltage rating as a site approval. Also ask for any required BIS evidence for the specific purchase.

  1. Measure the supply at the transfer point and note whether it is DC or AC, and its exact voltage.
  2. Write down the liquid to be moved and the flow rate needed in L/min.
  3. Match that flow to CE-40DC (40 L/min), CE-70-A-DC (70 L/min) or CE-80-DC (80 L/min).
  4. Pick the 12V or 24V version of the shortlisted model, then confirm its current rating against the supply and wiring.
  5. Check inlet and outlet size against your hose and fittings, then request a version-specific, GST-inclusive quote.

For example, if you need to move diesel at roughly 70 L/min through 3/4-inch hose already on site, CE-70-A-DC fits the flow and connection size; you would still confirm its current draw for your chosen 12V or 24V supply before ordering.

Common questions

Does the listed transfer-pump range include a 110V AC model?

The CE-40DC, CE-70-A-DC and CE-80-DC ratings specify DC voltage, not a 110V AC version.

Which listed equipment has an AC220V option?

The CE-204 and CE-206 dispensers offer AC220V, alongside DC12V and DC24V options.

Can I choose a pump from flow rate alone?

No. Check the available supply and the chosen version’s current, then match its liquid use and connection size to the job.

Do CE-40DC and CE-80-DC need the same wiring for their 12V versions?

No. CE-40DC draws 22A at 12V while CE-80-DC draws 44A at 12V, so each needs wiring and protection sized to its own rating.

Quick pick

  • 40 L/min: Consider CE-40DC for diesel or kerosene; choose its matching 12V or 24V version.
  • 70 L/min: Consider CE-70-A-DC; check liquid suitability and current for the chosen voltage.
  • 80 L/min: Consider CE-80-DC for diesel transfer; allow for its 1-inch connections.
  • AC220V with dispensing controls: Compare the CE-204 and CE-206 dispensers.
  • AC-only pump transfer: Identify a transfer pump with an explicit matching AC rating before purchase.